Hikvision HF-C104 4-Zone Conventional Fire Alarm Control Panel — 128-Device Capacity
₦229,900.00
HIKVISION HF-C104 KEY FEATURES
• Four conventional detection zones
• Up to 32 compatible devices per zone
• Maximum 128-device capacity
• Compatible conventional smoke and heat detectors
• Compatible manual call points
• Visual and audible alarm indications
• Local silence, reset and self-test
• Ethernet, RS-485 and USB interfaces
• Two fire bell output circuits
• Fire alarm and fault relay outputs
• Four auxiliary interfaces
• 24V DC/500mA auxiliary output
• Dual 12V/2.2Ah backup battery support
• Metal cabinet
• Up to 500m specified cable run
• -10°C to +55°C operating temperature
Description
Hikvision HF-C104 4-Zone Conventional Fire Alarm Control Panel
The Hikvision HF-C104 is a four-zone conventional fire alarm control panel designed for centralized monitoring and control of compatible fire detection devices in commercial, residential and institutional buildings.
Each of its four detection zones supports up to 32 compatible conventional devices, providing a maximum rated capacity of 128 devices across the system. This allows installers to organize smoke detectors, heat detectors and manual call points into identifiable areas for easier fire alarm monitoring and fault identification.
The panel provides visual and audible alarm indication, local silence, reset and self-test functions to assist building operators and maintenance personnel.
Its connectivity includes Ethernet, RS-485 and USB interfaces, along with fire bell outputs, alarm and fault relay outputs, auxiliary connections and a 24V DC output for compatible equipment.
The HF-C104 operates from a 110–240V AC mains supply and is designed to use two 12V/2.2Ah sealed lead-acid backup batteries for continued operation during a mains power interruption.
Its compact metal cabinet measures approximately 300 × 220 × 80mm, supporting installation in suitable indoor locations.
The Hikvision HF-C104 is suitable for professionally designed conventional fire alarm installations in offices, shops, schools, warehouses, apartment buildings and other facilities where zone-based fire detection is appropriate.
Important: This is a fire alarm control panel, not a complete fire alarm kit. Compatible detectors, manual call points, sounders, wiring and installation materials must be specified separately. Battery inclusion should also be confirmed with the supplier.
Installation, commissioning and testing must be performed by qualified fire alarm personnel in accordance with applicable codes and the manufacturer’s instructions.